                NOTE: A1000 battery is not hotswappable.

但是我的A1000后面的电池亮黄灯告警,这里为什么没有看见相关的信息?
messages中也没有发现。

 echo52 回复于:2005-04-13 17:37:38 Sun A 1000 接 两台sun Fire 280R , A1000配置6个硬盘。

SUN A1000的磁盘阵列一个硬盘闪黄灯,我怀疑是不是硬盘出现出现故障了

和sun的800联系了,他们也建议我换硬盘并把硬盘邮寄过来了。那么是不是我把业务停止了把服务器和盘阵断电,换上新的硬盘,再加电,数据是不时自动重构了?如下:

       Step1 .  停止vcs ,oracle , shutdown solaris 

          Step2 .  断电,换上新的硬盘

       Step3 .  加电,启动vcs,oracle . 照常跑应用,raid5自动重构数据。

各位指点!
还有我运行lad   rm6什么的,提示命令没有发现.why?

 lyh003473 回复于:2005-04-13 18:59:41 VCS双机根本不用停的,280也不用停,阵列也不用停,只在拔掉坏盘,加入新盘就行了

 kentao 回复于:2005-04-14 08:55:23 [quote:c510eb7948="echo52"]Sun A 1000 接 两台sun Fire 280R , A1000配置6个硬盘。

SUN A1000的磁盘阵列一个硬盘闪黄灯,我怀疑是不是硬盘出现出现故障了

和sun的800联系了,他们也建议我换硬盘并把硬盘邮寄过来了。那么是不是我把业务?.........[/quote:c510eb7948]


A1000换盘不需要断电!
下面是还盘步骤:
To Fix the Drive Failures With Recovery Guru

1. Start the Recovery Application.
RAID Module 1 is already selected.

2. Click Recovery Guru.
Checking displays until its diagnosis of the module’s condition is complete. You see
two separate Drive Failure entries instead of one Multiple Drive Failure in the
Failure column. Also, the first Drive Failure entry is highlighted and NO is
displayed in the Fixed? column.

3. Click Fix.
The Summary Report displays for this drive failure that provides the drive’s location
([1,1]; the affected LUN’s number, status, and RAID Level; and a summary of what
the recovery procedure will involve. You see that the LUN is Degraded and not
Dead; therefore, the failed drives are not in the same drive group. Furthermore, you
see that the LUN’s data should still be accessible.

4. Click OK.
Important Notes displays to summarize what you should consider before removing
the failed drive
Note – The type of recovery procedure required for drive failures depends on the
RAID Level of the affected logical unit and the number of drives failed in the same
drive group. Therefore, it is best to use Recovery Guru. For example, in a RAID 0
LUN, one drive failure causes the loss of all data. In a RAID 1, 3, or 5 LUN, one
drive failure causes the LUN to go to Degraded, but data is still accessible.

5. Click OK.
The Replacement Procedure For Drive At Location [1,1] provides a step-by-step
procedure to walk you through removing and replacing the failed drive. Carefully
follow each step to benefit from Recovery Guru’s analysis and verifications:
a. Verify that the new drive’s capacity matches the failed drive’s capacity.
b. Remove the failed drive.
c. Wait 30 seconds.
d. Insert the new drive into the drive canister.
Caution – Do not click OK in the Replacement Procedure window unless you have
physically replaced the failed drive. However, when you click OK, Recovery Guru