A1000更换电池的步骤是什么?[3]

[入库:2005年9月19日] [更新:2007年3月24日]

本文简介:

verifies whether or not the drive has been replaced. If Recovery Guru detects the
drive as not replaced, it displays a Drive Replacement Condition message that
suggests you verify the following:
The drive has indeed been physically replaced.
The drive does not have an incorrect capacity; that is, a capacity smaller than the
drive it is replacing.
Reconstruction has not yet started.


6. Click OK.
A display tells you that reconstruction has automatically started on the new drive
and you can click LUN Reconstruction in the Status Application to view the
reconstruction progress. For more information on what reconstruction involves, see
“Reconstruction” on page 23.

7. Click OK.
You return to the main Recovery Guru window. The Fixed? column updates to say
YES for the first Drive Failure entry and the second Drive Failure entry is
highlighted.

8. Click Fix.
The Summary Report for this drive failure shows the drive’s location is [2,1]. The
LUN is also Degraded.
Note – It is possible to have more than one failed drive in a RAID Module and the
logical unit(s) remain in the degraded mode. This occurs if the failed drives are not
in the same drive group. Also, it is possible to have more than one drive fail in a
RAID 1 logical unit and the logical unit remain Degraded, as long as the failed
drives are not in the same mirrored pair.

9. Continue following Recovery Guru’s instructions to replace this second failed
drive as you did for the first.
When you return to the main Recovery Guru window, the Fixed? column now
shows YES for both Drive Failure entries and neither entry is highlighted.

10. Click Recovery Guru again to verify that RAID Module 1 is now Optimal.
The display shows Optimal in the failure column. The Fix option is dimmed and you
cannot highlight the module for any action. Your module is again operating in a
normal condition.


另:rm6和lad命令在:/usr/lib/osa/bin下